Section Navigation

Browse



view old Literature server
logged in as: pbpl
logout
list users
M.P. Dunning

First Name: M.

Middle Name: P.

Last Name: Dunning

Full Name: M.P. Dunning

24-tag-hot tags:


Potential Duplicate Authors:

view citation format

6 papers
title: Beam compression experiments using the UCLA/ATF compressor
format: conference procceeding
conference:
year: 2006
13 authors: D. Schiller | E. Hemsing | J. B. Rosenzweig | M.P. Dunning | G. Andonian | A. Murokh | A.M. Cook | S. Reiche | M. Babzien | K. Kusche | V. Yakimenko | L. Palumbo | C. Vicario
abstract: We review recent experimental results from the BNL ATF using the compressor built by UCLA. The measurements discussed include: first observation of short wavelength coherent edge radiation angular/wavelength spectrum and spectrum, sub-100 fsec pulse-length coherent transition autocorrelation measurements, and longitudinal and transverse phase space distortions. Extension of these measurements, as well as those which can be made possible by a new X-band traveling wave deflector being developed in an industrial collaboration, are examined.
keywords: quindi  
Download | View | Details | edit | delete
title: RF AND MAGNETIC MEASUREMENTS ON THE SPARC PHOTOINJECTOR AND SOLENOID AT UCLA
format: conference procceeding
conference: 2005 Particle Accelerator Conference
year: 2005
8 authors: J. B. Rosenzweig | A.M. Cook | M.P. Dunning | P. Frigola | G. Travish | C. Sanelli | F. Tazzioli | D. T. Palmer
abstract: The rf photocathode gun and the solenoid for the SPARC project at INFN-LNF (Frascati) have been fabricated and undergone initial testing at UCLA. The advanced aspects of the design of these devices are detailed. Final diagnosis of the tuning of the RF gun performance, including operating mode frequency and field balance, is described. The emittance compensating solenoid magnet, which is designed to be tuned in longitudinal position by differential excitation of the coils, has been measured using Hall probe scans for field profiling, and pulsed wire methods to determine the field center. Comparisons between measurements and the predictions of design codes are made.
keywords:
Download | View | Details | edit | delete
title: Mitigation of RF Gun Breakdown by Removal of Tuning Rods in High Field Regions
format: conference procceeding
conference: 2007 Particle Accelerator Conference
year:
5 authors: A. M. Cook | M.P. Dunning | J. B. Rosenzweig | K. Serratto | P. Frigola
abstract: The pi-mode resonant frequency of the 1.6 cell SLAC/BNL/UCLA style RF photoinjector electron gun is conventionally tuned using cylindrical copper tuning pieces that extend into the full-cell cavity through holes in the side of the gun. This design begins to fail in many versions of this popular gun design at higher voltage levels, when the cavity undergoes electric breakdown in the vicinity of the tuners. In order to remove the tuners from the region of high electric field, mitigating this problem, one must change the full cell geometry significantly. We have investigated a method for accomplishing this, in which we stretch the gun structure to tune the resonant frequency up by over 2 MHz. We constructed a device to perform this stretching and tested the modified photoinjector in an RF test bed. We succeeded in putting approximately 8.4 MW of RF power into the gun, an improvement over the 4 MW routinely achieved with a similar gun using conventional tuning methods installed at the UCLA Neptune laboratory. Recent results in testing this gun with a magnesium cathode insert are reported as well.
keywords: pbpl  
Download | View | Details | edit | delete
title: MITIGATION OF ELECTRIC BREAKDOWN IN AN RF PHOTOINJECTOR BY REMOVAL OF TUNING RODS IN HIGH-FIELD REGIONS
format: preprint
year: 2007
5 authors: K. Serratto | P. Frigola | J. B. Rosenzweig | M.P. Dunning | A.M. Cook
abstract: The pi-mode resonant frequency of the 1.6 cell SLAC/BNL/UCLA style RF photoinjector electron gun is conventionally tuned using cylindrical copper tuning pieces that extend into the full-cell cavity through holes in the side of the gun. This design begins to fail in many versions of this popular gun design at higher voltage levels, when the cavity undergoes electric breakdown in the vicinity of the tuners. In order to remove the tuners from the region of high electric field, mitigating this problem, the full cell geometry must be changed significantly. We report on a method of accomplishing this, in which we use a mechanical device of custom design to stretch the cavity structure of an existing photoinjector in order to tune the resonant frequency up by over 2 MHz. We present results of testing the modified photoinjector in an RF test bed with both copper and magnesium cathodes, succeeding in putting approximately 8 - 10 MW of RF power into the gun. This is an improvement over the 4 MW routinely achieved in a similar gun using conventional tuning methods installed at the UCLA Neptune laboratory.
keywords: pbpl  
Download | View | Details | edit | delete
title: Chicane Radiation Measurements with a Compressed Electron Beam at the BNL ATF
format: journal article
year: 2007
12 authors: G. Andonian | R. B. Agustsson | A. M. Cook | M. P. Dunning | E. Hemsing | A. Y. Murokh | S. Reiche | J. B. Rosenzweig | M. Babzien | K. Kusche | R. Malone | V. Yakimenko
abstract:
keywords: pbpl  
Details | edit | delete
title: Future FEL Studies at the VISA Experiment in the SASE and Seeded Modes
format: journal article
year: 2006
9 authors: G. Andonian | M. P. Dunning | A. Y. Murokh | C. Pellegrini | S. Reiche | J. B. Rosenzweig | M. Babzien | I. Ben-Zvi | V. Yakimenko
abstract: The VISA (Visible to Infrared SASE Amplifier) experiment at BNL (Brookhaven National Laboratory) has previously demonstrated saturation at 840 nm in 2001. Further SASE studies, in 2003, have demonstrated an anomalously large bandwidth spread of the FEL spectrum due to off-angle emissions. This paper disseminates the current and future program of the VISA program at BNL. This includes a study of a seeded FEL, using a 1 micron YAG laser as a seed, and the accompanying diagnostics to characterize the radiation. Diagnostics include the double differential spectrometer, a mode converter to investigate the orbital angular momentum of light in the FEL, and an optical pepper-pot for coherence measurements. As usual, start-to-end simulations are presented.
keywords: pbpl  
Download | View | Details | edit | delete