abstract:
|
Two identical Faraday cups have been designed and built to stop a 20 meV, 1 nC electron pulse beam, accelerated at the UCLA Particle Beam Physics Laboratory (PBPL). The dumps were also designed to serve as charge measuring diagnostics. Each device is a simple design using a carbon graphite core, Delrin insulation, vacuum tubing components, and lead brick shielding. The graphite core stops the beam while producing manageable secondary radiation sources. The overall design considerations and final solutions are summarized.
|