title: Initial operation and beam characteristics of the UCLA S-band RF photo-injector
format: conference procceeding
conference: 1993 Particle Accelerator Conference
year: 1993
10 authors: C. Pellegrini | N. Barov | S. C. Hartman | S. Park | J. B. Rosenzweig | G. Travish | R. Zhang | P. Davis | C. Joshi | G. Hairapetian
abstract: The UCLA RF photo-injector system has been commissioned. All of the sub-components such as the high power RF, pico-second laser, RF photo-injector cavity, diagnostics, and supporting hardware have been tested and are operational. We briefly discuss the performance of the various components since the details of each subsystem are very lengthy. The laser delivers a sub 4 ps pulse containing 0-300 mu J of energy per pulse. The photo-injector produces 0-3 nC per bunch with an RF induced emittance of 1.5 pi (mm-mrad). (5 References).